ESD safety shoes only work if the floor completes the circuit. Phil Industries supplies dissipative safety footwear in Singapore — S1, S2 and S3 ratings plus cleanroom-grade uppers — and can advise on the flooring that makes them effective.

ESD safety shoes supplied in Singapore

🥾 Safety ratings explained

Rating What it adds Typical use
SB Toe cap only Basic protection
S1 Toe cap + antistatic + closed heel Dry indoor production, electronics
S2 S1 + water penetration resistance Damp areas
S3 S2 + penetration-resistant midsole Heavier industrial floors
Cleanroom Dissipative, low-particle upper ISO-classified rooms

📊 Where the resistance has to sit

Person-to-ground resistance path, ANSI/ESD S20.20

Insulative floor Circuit broken — shoes do nothing
Dissipative floor + ESD shoes Within limit — charge drains
Wrist strap at bench Direct path — seated work

Illustrative, not measured values. ANSI/ESD S20.20 sets the person-to-ground limit; verify with a foot tester on entry.

👟 Shoes or wrist strap?

  • Standing or moving work — ESD footwear plus dissipative flooring. A strap would tether the operator.
  • Seated bench work — a wrist strap gives the direct path.
  • Most S20.20 programmes use both, footwear on the floor and a strap at the bench.

⚠️ Limitations worth knowing

  • The floor completes the circuit. ESD shoes on an insulative floor do nothing.
  • Test daily. Operators should verify footwear at a foot tester on entry to the EPA.
  • Socks matter. Thick insulating socks can break the path through the insole.
  • Wear degrades performance. Re-test rather than assume.

📚 Standards referenced

ANSI/ESD S20.20 ESD control programme — person-to-ground requirements
IEC 61340-5-1 Protection of electronic devices from electrostatic phenomena
EN ISO 20345 Safety footwear specification and SB/S1/S2/S3 ratings
ANSI/ESD STM97.1 Footwear and flooring system resistance in combination

❓ Common questions

Do ESD shoes work on any floor?
No. They need a dissipative or conductive floor. On vinyl or epoxy that is insulative, the circuit never closes.

How often should footwear be tested?
Every shift, at the EPA entrance. It takes seconds and it is the first thing an auditor asks to see.

Which rating do I need for an electronics line?
S1 covers most dry indoor production. Go to S2 or S3 where there is water or floor debris.

Do you stock these in Singapore?
Yes, common sizes are held locally with same-day quotation.

✅ Get sized and quoted

Send your sizes, rating and floor type. Call +65 6555 1745 or email kenneth@phil-industries.com.sg.